FLIR A400/A700 SMART THERMAL SENSOR

The FLIR A400/A700 Thermal Smart Sensor Camera has the features that automation solution providers need for complex monitoring applications, including elevated skin temperature screening when used as an adjunct to other body temperature screening tools, critical infrastructure, product quality, and early fire detection. The Smart Sensor configuration includes multiple measurement tools and alarms while also providing computing-on-the-edge, with analytics performed at the camera level for immediate results. With a range of lens choices, motorized focus control, and unrivaled connectivity, A400/A700 cameras offer unmatched power and flexibility. Easy configuration allows you to tailor this monitoring system to your company’s quality, productivity, maintenance, and safety needs.


Speed Up Decision-Making, Reduce Downtime, Improve Product Quality

FLEXIBLE MEASUREMENT FEATURES FOR A WIDE RANGE OF APPLICATIONS

Includes options to adjust measurements and alarms based on a reference temperature source (advanced)

ADVANCED ANALYTICS FOR IMPROVED DECISIONS SUPPORT

Edge analytics with features such as a polygon function (advanced) help you make immediate, informed decisions

WORLD-CLASS THERMAL IMAGING

Provides exceptional image quality with up to 640 × 480 (307,200 pixels) and superior measurement accuracy (<±2°C)



SPECIFICATIONS

GENERAL

Contrast Enhancement

FSX® / Histogram equalization (IR only)

OVERVIEW

Accuracy

±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

Alarm Functions

On any selected measurement function, digital in, and internal camera temperature

Alarm Output

• Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • Store image or video

Base Mounting

4× M4 on 4 sides

Encoding

H.264, MPEG4, or MJPEG

Housing Material

Aluminium

IR Resolution

320 × 240

Object Temperature Range

-20°C to 120°C (-4°F to 248°F), 0°C to 650°C (32°F to 1202°F), 300°C to 2000°C (572°F to 3632°F)

Size (L x W x H)

123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)

Thermal Sensitivity/NETD

Lens dependent

Web Interface

Yes

Weight

0.82 kg (1.8 lb), camera only

Multi-Streaming

Yes

CONNECTIONS & COMMUNICATIONS

Digital I/O Connector Type

M12 12-pin A-coded, Male (shared with external power)

Digital I/O Isolation Voltage

500 VRMS

Digital Input Purpose

NUC, NUC disable, alarm

Digital Inputs

2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 v

Digital Output Purpose

• As a function of alarm, output to external device • Fault (NC)

Digital Outputs

3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

Ethernet

For control, result, image, and power

Ethernet Communication

TCP/IP socket-based FLIR proprietary

Ethernet Connector Type

M12 8-pin X-coded, female; RP-SMA, female

Ethernet Power

Power over Ethernet, PoE IEEE 802.3af class 3

Ethernet Protocols

• EtherNet/IP • IEEE 1588 • Modbus TCP Slave • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP

Ethernet Standard

IEEE 802.3

Ethernet Type

1000 Mbps

RS-232

NA

WIFI

Optional feature purchased separately. RP-SMA, female connector

Ethernet Interface

Wired, Wi-Fi (optional)

Multicast

Yes

ENVIROMENTAL

Atmospheric Transmission Correction

Based on inputs of distance, atmospheric temperature, and relative humidity

EMC

• ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)

Emissivity Correction

Variable from 0.01 to 1.0

Encapsulation

IEC 60529, IP 54, IP66 with accessory

Humidity (Operating and Storage)

IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles

Operating Temperature Range

-20°C to 50°C (–4°F to 122°F): • -20°C to 40°C (-4°F to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) Maximum camera case temperature: 65°C (149°F)

Radio Spectrum

• FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)

Shock

IEC 60068-2-27, 25 g

Tripod Mounting

UNC ¼″-20 on 2 sides

Vibration

• IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)

Corrosion

• ISO 12944 C4 G or H • EN60068-2-11

FILE STORAGE & DATA TRANSFER

Video Storage

Records up to 10 H.264 videos; storage as function of alarm — 5 sec. before alarm and 5 sec. after alarm.

IMAGING & OPTICAL

Available Lenses

6°, 24°, 14°, 42°

Detector Pitch

24 µm

Focal Plane Array (FPA)

Uncooled microbolometer

Focus

One-shot contrast, motorized, and manual

Image Frequency

30 Hz

Radiometric IR video streaming

NA

Readout

Measurement results: • Ethernet/IP (pull) • Modbus TCP slave (pull) • MQTT (push) • Query over REST API (pull) • Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), read access only • Web interface

Spectral Range

7.5–14 µm

Streaming Resolution

Video stream 0: 640 × 480 pixels Video stream 1: 1280 × 960 pixels

Video Streaming

RTSP protocol

Overlay

With / Without

Visible Camera

Optional accessory

MEASUREMENT & ANALYSIS

External Optics & Windows Correction

Based on input of optics/window transmission and temperature

Measurement Corrections

Global object parameters; local parameters per analyze function

Measurement Presets

Yes

Reflected Apparent Temperature Correction

Based on input of reflected temperature

Measurement Tools

0 spotmeters, 10 boxes, 3 Deltas (difference any value/reference/external lock), 1 isotherm (above/below/interval), 1 iso-coverage, 1 reference temperature

Automatic Hot & Cold Detection

Max./min. temperature value and position shown within box

POWER

External Power Operation

24/48 V DC 8 W max

Power Connection

M12 12-pin A-coded, male (shared with Digital I/O)

Power Consumption

• 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical

External Voltage

Allowed range 18–56 V DC

RADIOMETERY

Image Source

Video stream 0: visual / IR / MSX® (visual camera is an optional feature) Video stream 1: visual

STORAGE MEDIA

Image Storage

Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web)